THERMOR General-catalogue 2021-2022

F E Ø C D 206 A B FRONTAL CONTROL KNOB For more information see p. 71 Model Diameter (Ø) Dimensions (mm) Net weight (kg) ERP Energy class Profile A B C D E F 80 433 791 590 251 457 165 451 22 C M 100 433 948 740 251 457 165 451 25.5 C L DIMENSIONS INDIRECT & COMBI WATER HEATER 80 TO 100 VERTICAL WALL-MOUNTED INSTALLATION DIMENSIONS (in mm) TECHNICAL DATA Model Heating element type Heating time Δ t 20°C secondary 45°C Heating time Δ t 50°C secondary 45°C Power (kW) primary 90°C - 2m 3 /h secondary 45°C Power (kW) primary 80°C - 2m 3 /h secondary 45°C Continuous flow (L/h) primary 90°C secondary 45°C Flow in 10 minutes (L) Power (kW) Primary 90°C - 2m 3 /h Primary 80°C - 2m 3 /h Δ t = 30°C Δ t = 50°C Δ t = 30°C Δ t = 50°C 80 sheathed 1h16 3h10 17.5 13.6 431 93 11.6 19.4 11.6 19.4 100 sheathed 2h54 7h20 17.5 13.6 431 103 11.6 19.4 11.6 19.4 Model Output (1) (W) Electric supply (V/Hz) Energy consumption (kWh/24 h) Max temperature of use Work pressure (bar) Inner volume of coil (L) Surface area of coil (m 2 ) Pressure loss at 2m 3 /h (mbar) Pressure loss at 1 m 3 /h (mbar) Coil maxi working pressure (bar) Standard testing pressure (bar) 80 1500 230 (220/240) 1.61 90°C 8 2.7 0.35 20 < 15 6 12 100 1500 230 (220/240) 2.02 90°C 8 2.7 0.35 20 < 15 6 12 O'PRO TECHNOLOGY O’Pro exclusive anti-corrosive system balances out the electrical potential of the tank and immersion heating element. Thus, the magnesium anode life is considerably increased and protection against corrosion is reinforced. (1) Only for combi models C +50% Tank lifetime ErP Compliant 95 INDIRECT & COMBI WATER HEATERS

RkJQdWJsaXNoZXIy NTAwMTk1